Southwire HVAC Wire & Cable

Southwire HVAC wire and cable products are designed to save you time, money and hassle.

Southwire has a long history of innovating to meet customer needs. Our vast selection of HVAC products keeps pace with construction and engineering changes like ductless heating and cooling. We can supply any type of HVAC wire and cable to meet your needs. This includes products like our SIMpull Tstat® wire and our award winning EZ-In™ Mini-Split cables, along with the necessary hand tools and connectors you need to get the job done.

EZ-IN™ SHIELDED
MINI-SPLIT CABLE

The most innovative HVAC offering exclusively from Southwire – now shielded! The shielded construction allows for protection from noise and electrical interference when running mini-split cable alongside power cable.

EZ-IN™ MINI-SPLIT
CABLE 600 VOLT
Southwire HVAC Wire and Cable - EZin Mini-Split Cable 600 Volt for Installations Made Easy

Southwire’s EZ-In™ Mini-Split Cable can be installed without the use of conduit and may be installed indoors and outdoors in wet locations.

SIMpull
TStat™ WIRE
Southwire HVAC Wire and Cable - SIMpull Thermostat™ Wire

SIMpull Thermostat™ Wire is a class 2 power-limited circuit cable for use in thermostat control applications.

MINI-SPLIT WIRE
300 VOLT SHIELDED
Southwire HVAC Wire and Cable - Mini Split Wire 300 Volt Shielded

Mini-Split Wire is a class 3 power-limited circuit cable used with HVAC Mini-Split systems. Also can be used in security and audio applications.

MINI-SPLIT TRAY
CABLE 600 VOLT
Southwire HVAC Wire and Cable - Mini-Split Tray Cable 600 Volt

Tray Cable is a multi-conductor control, signal or power cable rated for 600 volts. May be installed in raceways, conduit, cable trays, and outdoor locations where supported by a messenger wire. Also suitable for direct burial. Temperature rating at 75°C wet locations / 90oC dry locations.

THERMOSTAT WIRE
RISER RATED
Southwire HVAC Wire and Cable - Thermostat Wire Riser Rated

Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications from floor to floor and up access shafts without conduit

THERMOSTAT WIRE
RISER RATED – SHIELDED
Southwire HVAC Wire and Cable - Thermostat Wire Riser Rated Shielded

Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications.

THERMOSTAT WIRE
PLENUM RATED
Southwire HVAC Wire and Cable - Thermostat Wire Plenum Rated

Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications.

THERMOSTAT WIRE
PLENUM RATED – SHIELDED
Southwire HVAC Wire and Cable - Thermostat Wire Plenum Rated Shielded

Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications.

ULTRA-WHIP ® PRE-ASSEMBLED
NON-METALLIC HOOK-UP WHIPS
Southwire HVAC Wire and Cable - Ultra Whip Pre Assembled Non Metallic Hook Up Whips

Complete assembly delivered from the factory ready to install. Includes 12″ wire leads at each end and LFNC-B Fittings for easy and hassle-free hook-ups. Resistant to rust, cracks, and separation. Non-metallic raceway is non-conducting. Commonly used for connecting air conditioners, pumps, motors, compressors, swimming pool equipment and similar equipment.

THHN/THWN/TWN75/T90
Southwire HVAC Wire and Cable - THHN THWN TWN7 T90

Southwire Type THHN or THWN-2* conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code®2.

TFFN/TFN/TEWN
Southwire HVAC Wire and Cable - TFFN TFN TEWN

Southwire Type TFFN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the National Electrical Code®2.

ROMEX ® SIMPULL ®
TYPE NM-B
Southwire HVAC Wire and Cable - Romex SIMPull Type NM-B

Southwire’s Romex® SIMpull® Type NM-B (non-metallic sheathed cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code®1.

SEOPRENE
SEOOW
Southwire HVAC Wire and Cable - Seoprene SEOOW

Quantum TPE ® Type SEOOW – Permitted for use as specified by Article 400 and related articles of the National Electrical Code®. Typical applications include wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential.

SEOPRENE
SJEOOW
Southwire HVAC Wire and Cable - Seoprene SJEOOW

Quantum TPE ® Type SJEOOW – Permitted for use as specified by Article 400 and related articles of the National Electrical Code®. Some typical applications include wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors, and temporary electrical power and lighting installations for construction sites. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential.

ULTRATITE ®
TYPE NM
Southwire HVAC Wire and Cable - Ultratite Type NM

For the installation and protection of electrical conductors in circuits of 600 volts nominal, or less. Motor circuits – for conductors of motor feeders, branch and control circuits. Where the conditions of installation, operation, or maintenance require flexibility or protection from liquids, vapors, solids, or weather. Agricultural buildings per NEC® 547.5. Used in industrial and commercial applications for conveyors, blowers, cranes, air conditioners, machine tooling and lubrication equipment. Exposed or concealed installations. Applications requiring movement, crossover connections, or tight bends. For direct burial and encased in concrete.

ARMORLITE ®
TYPE MC
Southwire HVAC Wire and Cable - Armorlite Type MC

Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings. Power, lighting, control, and signal circuits. Fished or embedded in plaster. Concealed or exposed installations.

COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E PLENUM RATED – CMP
Southwire HVAC Wire and Cable - Communication Circuits Enhanced Category 5E Riser Rated CMP

1000 base-T (Gigabit Ethernet); 100 base-T (Fast Ethernet); 10 base-T (IEEE 802.3); 4/16 Mbps token ring (IEEE 802.5); 100 VG-Any LAN; 100 Mbps TP-PMD (ANSI X3T9.5); 55/155 Mbps ATM; voice, ISDN, video to desktop, multimedia.

COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E RISER RATED – CMR
Southwire HVAC Wire and Cable - Communication Circuits Enhanced Category 5E Riser Rated CMR

1000 base-T (Gigabit Ethernet); 100 base-T (Fast Ethernet); 10 base-T (IEEE 802.3); 4/16 Mbps token ring (IEEE 802.5); 100 VG-Any LAN; 100 Mbps TP-PMD (ANSI X3T9.5); 55/155 Mbps ATM; voice, ISDN, video to desktop, multimedia.

TEMPERATURE CONTROL CABLES PLENUM AND NON-PLENUM RATED
Southwire HVAC Wire and Cable - Temperature Control Cables Plenum and Non-Plenum Rated

Building automation systems, commercial controls, network and automation control systems.

PIGTAILS – POWER
SUPPLY CORD SPT-3
Southwire HVAC Wire and Cable - Pigtails Power Supply Cord SPT-3

Southwire’s SPT-3 Power Supply Cords (pigtails) can be used for general purpose use. For multiple uses and suitable for a replacement power cord for air conditioners, refrigerators, freezers, microwaves.

PV PHOTOVOLTAIC WIRE
UL/TUV CERTIFIED
Southwire HVAC Wire and Cable - PV Photovoltaic Wire UL TUV Certified

For use in solar power applications. Rated for exposed or concealed wiring in wet or dry locations. Rated for direct burial for UL.

PV PHOTOVOLTAIC WIRE
2000 VOLT XLP – COPPER
Southwire HVAC Wire and Cable - PV Photovoltaic Wire 2000 Volt XLP Copper

For use in solar power applications per NEC® Article 690. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

PV PHOTOVOLTAIC WIRE
600 VOLT XLP
Southwire HVAC Wire and Cable - PV Photovoltaic Wire 600 Volt XLP

For use in solar power applications. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

PV PHOTOVOLTAIC WIRE
1000 VOLT TYPE RPVU – BLACK
Southwire HVAC Wire and Cable - PV Photovoltaic Wire 1000 Volt Type RPVU Black

For use in solar power applications. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

PV PHOTOVOLTAIC WIRE
2000 VOLT EPR – COPPER
Southwire HVAC Wire and Cable - PV Photovoltaic Wire 2000 Volt EPR Copper

For use in solar power applications. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

EZ-IN™ SHIELDED
MINI-SPLIT CABLE

The most innovative HVAC offering exclusively from Southwire – now shielded! The shielded construction allows for protection from noise and electrical interference when running mini-split cable alongside power cable.

EZ-IN™ MINI-SPLIT
CABLE 600 VOLT
Southwire HVAC Wire and Cable - EZin Mini-Split Cable 600 Volt for Installations Made Easy

Southwire’s EZ-In™ Mini-Split Cable can be installed without the use of conduit and may be installed indoors and outdoors in wet locations.

SIMpull
TStat™ WIRE
Southwire HVAC Wire and Cable - SIMpull Thermostat™ Wire

SIMpull Thermostat™ Wire is a class 2 power-limited circuit cable for use in thermostat control applications.

MINI-SPLIT WIRE
300 VOLT SHIELDED
Southwire HVAC Wire and Cable - Mini Split Wire 300 Volt Shielded

Mini-Split Wire is a class 3 power-limited circuit cable used with HVAC Mini-Split systems. Also can be used in security and audio applications.

MINI-SPLIT TRAY
CABLE 600 VOLT
Southwire HVAC Wire and Cable - Mini-Split Tray Cable 600 Volt

Tray Cable is a multi-conductor control, signal or power cable rated for 600 volts. May be installed in raceways, conduit, cable trays, and outdoor locations where supported by a messenger wire. Also suitable for direct burial. Temperature rating at 75°C wet locations / 90oC dry locations.

THERMOSTAT WIRE
RISER RATED
Southwire HVAC Wire and Cable - Thermostat Wire Riser Rated

Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications from floor to floor and up access shafts without conduit

THERMOSTAT WIRE
RISER RATED – SHIELDED
Southwire HVAC Wire and Cable - Thermostat Wire Riser Rated Shielded

Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications.

THERMOSTAT WIRE
PLENUM RATED
Southwire HVAC Wire and Cable - Thermostat Wire Plenum Rated

Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications.

THERMOSTAT WIRE
PLENUM RATED – SHIELDED
Southwire HVAC Wire and Cable - Thermostat Wire Plenum Rated Shielded

Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications.

ULTRA-WHIP ® PRE-ASSEMBLED
NON-METALLIC HOOK-UP WHIPS
Southwire HVAC Wire and Cable - Ultra Whip Pre Assembled Non Metallic Hook Up Whips

Complete assembly delivered from the factory ready to install. Includes 12″ wire leads at each end and LFNC-B Fittings for easy and hassle-free hook-ups. Resistant to rust, cracks, and separation. Non-metallic raceway is non-conducting. Commonly used for connecting air conditioners, pumps, motors, compressors, swimming pool equipment and similar equipment.

THHN/THWN/TWN75/T90
Southwire HVAC Wire and Cable - THHN THWN TWN7 T90

Southwire Type THHN or THWN-2* conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code®2.

TFFN/TFN/TEWN
Southwire HVAC Wire and Cable - TFFN TFN TEWN

Southwire Type TFFN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the National Electrical Code®2.

ROMEX ® SIMPULL ®
TYPE NM-B
Southwire HVAC Wire and Cable - Romex SIMPull Type NM-B

Southwire’s Romex® SIMpull® Type NM-B (non-metallic sheathed cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code®1.

SEOPRENE
SEOOW
Southwire HVAC Wire and Cable - Seoprene SEOOW

QUANTUM TPE ® TYPE SEOOW

Permitted for use as specified by Article 400 and related articles of the National Electrical Code®. Typical applications include wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential.

SEOPRENE
SJEOOW
Southwire HVAC Wire and Cable - Seoprene SJEOOW

QUANTUM TPE ® TYPE SJEOOW

Permitted for use as specified by Article 400 and related articles of the National Electrical Code®. Some typical applications include wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors, and temporary electrical power and lighting installations for construction sites. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential.

ULTRATITE ®
TYPE NM
Southwire HVAC Wire and Cable - Ultratite Type NM

For the installation and protection of electrical conductors in circuits of 600 volts nominal, or less. Motor circuits – for conductors of motor feeders, branch and control circuits. Where the conditions of installation, operation, or maintenance require flexibility or protection from liquids, vapors, solids, or weather. Agricultural buildings per NEC® 547.5. Used in industrial and commercial applications for conveyors, blowers, cranes, air conditioners, machine tooling and lubrication equipment. Exposed or concealed installations. Applications requiring movement, crossover connections, or tight bends. For direct burial and encased in concrete.

ARMORLITE ®
TYPE MC
Southwire HVAC Wire and Cable - Armorlite Type MC

Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings. Power, lighting, control, and signal circuits. Fished or embedded in plaster. Concealed or exposed installations.

COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E PLENUM RATED – CMP
Southwire HVAC Wire and Cable - Communication Circuits Enhanced Category 5E Riser Rated CMP

1000 base-T (Gigabit Ethernet); 100 base-T (Fast Ethernet); 10 base-T (IEEE 802.3); 4/16 Mbps token ring (IEEE 802.5); 100 VG-Any LAN; 100 Mbps TP-PMD (ANSI X3T9.5); 55/155 Mbps ATM; voice, ISDN, video to desktop, multimedia.

COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E RISER RATED – CMR
Southwire HVAC Wire and Cable - Communication Circuits Enhanced Category 5E Riser Rated CMR

1000 base-T (Gigabit Ethernet); 100 base-T (Fast Ethernet); 10 base-T (IEEE 802.3); 4/16 Mbps token ring (IEEE 802.5); 100 VG-Any LAN; 100 Mbps TP-PMD (ANSI X3T9.5); 55/155 Mbps ATM; voice, ISDN, video to desktop, multimedia.

TEMPERATURE CONTROL CABLES PLENUM AND NON-PLENUM RATED
Southwire HVAC Wire and Cable - Temperature Control Cables Plenum and Non-Plenum Rated

Building automation systems, commercial controls, network and automation control systems.

PIGTAILS – POWER
SUPPLY CORD SPT-3
Southwire HVAC Wire and Cable - Pigtails Power Supply Cord SPT-3

Southwire’s SPT-3 Power Supply Cords (pigtails) can be used for general purpose use. For multiple uses and suitable for a replacement power cord for air conditioners, refrigerators, freezers, microwaves.

PV PHOTOVOLTAIC WIRE
UL/TUV CERTIFIED
Southwire HVAC Wire and Cable - PV Photovoltaic Wire UL TUV Certified

For use in solar power applications. Rated for exposed or concealed wiring in wet or dry locations. Rated for direct burial for UL.

PV PHOTOVOLTAIC WIRE
2000 VOLT XLP – COPPER
Southwire HVAC Wire and Cable - PV Photovoltaic Wire 2000 Volt XLP Copper

For use in solar power applications per NEC® Article 690. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

PV PHOTOVOLTAIC WIRE
600 VOLT XLP
Southwire HVAC Wire and Cable - PV Photovoltaic Wire 600 Volt XLP

For use in solar power applications. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

PV PHOTOVOLTAIC WIRE
1000 VOLT TYPE RPVU – BLACK
Southwire HVAC Wire and Cable - PV Photovoltaic Wire 1000 Volt Type RPVU Black

For use in solar power applications. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

PV PHOTOVOLTAIC WIRE
2000 VOLT EPR – COPPER
Southwire HVAC Wire and Cable - PV Photovoltaic Wire 2000 Volt EPR Copper

For use in solar power applications. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

WIN SOUTHWIRE HVAC TOOLS

Grand Prize*:

Open top tool bag filled with Southwire tools

Weekly Prizes:

Southwire tool bag backpack and $50 Visa gift card

 

Giveaway runs September 6th to October 17th. Weekly drawings will be held each Wednesday. Grand prize winner will be announced October 18th. 

Click here for official rules.

We never share this data with 3rd part companies.

*Actual tools may differ from those shown above.